{"id":34023,"date":"2023-07-04T09:52:12","date_gmt":"2023-07-04T09:52:12","guid":{"rendered":"https:\/\/woodcomm.ie\/catalogue\/?post_type=product&#038;p=34023"},"modified":"2024-12-02T06:02:54","modified_gmt":"2024-12-02T06:02:54","slug":"fiberxpert-otdr-5000","status":"publish","type":"product","link":"https:\/\/woodcomm.ie\/catalogue\/product\/fiberxpert-otdr-5000\/","title":{"rendered":"Softing FiberXpert OTDR 5000"},"content":{"rendered":"<div id=\"c3680\" class=\"default-content-element\">\n<div class=\"ce-textpic ce-left ce-above\">\n<h2><strong><span style=\"font-size: 26px;\">Softing FiberXpert OTDR 5000 for multimode\/single mode 850\/1300\/1310\/1550nm<\/span><\/strong><\/h2>\n<ul>\n<li><span style=\"font-size: 16px;\">Standard-compliant tier 2 measurement of fiber optic cables<\/span><\/li>\n<li class=\"ce-bodytext\">Tabular list of link events including their evaluation<\/li>\n<li class=\"ce-bodytext\">Graphical display of reflection curve for a length-dependent evaluation of all events in terms of reflection and attenuation<\/li>\n<li class=\"ce-bodytext\">Automatic pass\/fail analysis of measurement results in accordance with the TIA\/IEC limits<\/li>\n<li class=\"ce-bodytext\">Automatic macrobend identification<\/li>\n<li class=\"ce-bodytext\">Integrated attenuation analyzer<\/li>\n<li class=\"ce-bodytext\">Professional measurement protocols thanks to eXport evaluation software<\/li>\n<li class=\"ce-bodytext\">Large color touch display<\/li>\n<li class=\"ce-bodytext\">Optional optical fiber microscope including adapter for the most common fiber optic connectors<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<article id=\"c3689\" class=\"default-content-element si-detail-list frame frame-default frame-type-mask_si_detail_list frame-layout-0 \">\n<h2>General (Typical at 25\u00b0C)<\/h2>\n<div class=\"table-responsive\">\n<table>\n<tbody>\n<tr>\n<td class=\"si-detail-list-title \">Weight<\/td>\n<td class=\"si-detail-list-description\">0.4 kg (0.88 lb)<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Dimensions (w \u00d7 h \u00d7 d)<\/td>\n<td class=\"si-detail-list-description\">128x134x40 mm<br \/>\n(5&#215;5.28&#215;1.58 in)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/article>\n<article id=\"c3690\" class=\"default-content-element si-detail-list frame frame-default frame-type-mask_si_detail_list frame-layout-0 \">\n<h2>Optical Interfaces<\/h2>\n<div class=\"table-responsive\">\n<table>\n<tbody>\n<tr>\n<td class=\"si-detail-list-title \">Interchangeable optical connectors<\/td>\n<td class=\"si-detail-list-description\">FC, SC, DIN, and ST<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/article>\n<article id=\"c3691\" class=\"default-content-element si-detail-list frame frame-default frame-type-mask_si_detail_list frame-layout-0 \">\n<h2>Technical Characteristics<\/h2>\n<div class=\"table-responsive\">\n<table>\n<tbody>\n<tr>\n<td class=\"si-detail-list-title \">Laser safety class (21 CFR)<\/td>\n<td class=\"si-detail-list-description\">Class 1<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Distance units<\/td>\n<td class=\"si-detail-list-description\">Kilometers, feet, and miles<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Group index range<\/td>\n<td class=\"si-detail-list-description\">1.300000 to 1.700000 in 0.00001 steps<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Number of data points<\/td>\n<td class=\"si-detail-list-description\">Up to 128,000 data points<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Distance measurement<\/td>\n<td class=\"si-detail-list-description\">Automatic or dual cursor<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Display range<\/td>\n<td class=\"si-detail-list-description\">3.25 m to 260 km<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Cursor resolution<\/td>\n<td class=\"si-detail-list-description\">1 cm<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Sampling resolution<\/td>\n<td class=\"si-detail-list-description\">4 cm<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Accuracy<\/td>\n<td class=\"si-detail-list-description\">\u00b11 m \u00b1 10-5 x distance \u00b1 sampling resolution<br \/>\n(excluding group index uncertainties)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/article>\n<article id=\"c3692\" class=\"default-content-element si-detail-list frame frame-default frame-type-mask_si_detail_list frame-layout-0 \">\n<h2>Attenuation Measurement<\/h2>\n<div class=\"table-responsive\">\n<table>\n<tbody>\n<tr>\n<td class=\"si-detail-list-title \">Automatic, manual, 2-point, 5-point, and LSA<\/td>\n<td class=\"si-detail-list-description\"><\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Display range<\/td>\n<td class=\"si-detail-list-description\">1.25 dB to 55 dB<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Display resolution<\/td>\n<td class=\"si-detail-list-description\">0.001 dB<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Cursor resolution<\/td>\n<td class=\"si-detail-list-description\">0.001 dB<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Linearity<\/td>\n<td class=\"si-detail-list-description\">\u00b10.03 dB\/dB<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Threshold<\/td>\n<td class=\"si-detail-list-description\">0.01 to 5.99 dB in 0.01 dB steps<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/article>\n<article id=\"c3693\" class=\"default-content-element si-detail-list frame frame-default frame-type-mask_si_detail_list frame-layout-0 \">\n<h2>Reflectance\/ORL Measurements<\/h2>\n<div class=\"table-responsive\">\n<table>\n<tbody>\n<tr>\n<td class=\"si-detail-list-title \">Reflectance accuracy<\/td>\n<td class=\"si-detail-list-description\">\u00b12 dB<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Display resolution<\/td>\n<td class=\"si-detail-list-description\">0.01 dB<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Threshold<\/td>\n<td class=\"si-detail-list-description\">\u221211 to \u221299 dB in 1 dB steps<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/article>\n<article id=\"c3694\" class=\"default-content-element si-detail-list frame frame-default frame-type-mask_si_detail_list frame-layout-0 \">\n<h2>CW Source<\/h2>\n<div class=\"table-responsive\">\n<table>\n<tbody>\n<tr>\n<td class=\"si-detail-list-title \">CW Source output power level<\/td>\n<td class=\"si-detail-list-description\">\u22123.5 dBm<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Operating modes<\/td>\n<td class=\"si-detail-list-description\">CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz, TWINTest<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/article>\n<article id=\"c3695\" class=\"default-content-element si-detail-list frame frame-default frame-type-mask_si_detail_list frame-layout-0 \">\n<h2>Power Meter<\/h2>\n<div class=\"table-responsive\">\n<table>\n<tbody>\n<tr>\n<td class=\"si-detail-list-title \">Power level range<\/td>\n<td class=\"si-detail-list-description\">MM: \u22123 to \u221230 dBm<br \/>\nSM: \u22122 to \u221250 dBm<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Calibrated wavelengths<\/td>\n<td class=\"si-detail-list-description\">MM: 850 and 1300 nm<br \/>\nSM: 1310, 1490, 1550, 1625, 1650 nm<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Measurement accuracy<\/td>\n<td class=\"si-detail-list-description\">MM: \u00b11 dB (using a mode conditioner)<br \/>\nSM: \u00b10.5 dB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/article>\n<article id=\"c3696\" class=\"default-content-element si-detail-list frame frame-default frame-type-mask_si_detail_list frame-layout-0 \">\n<h2>Quad OTDR Module (typical at 25\u00b0C)<\/h2>\n<div class=\"table-responsive\">\n<table>\n<tbody>\n<tr>\n<td class=\"si-detail-list-title \">Central wavelength (Laser at 25\u00b0C)<\/td>\n<td class=\"si-detail-list-description\">MM:850\/1300 \u00b130 nm<br \/>\nSM:1310\/1550 \u00b120 nm<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Pulse width<\/td>\n<td class=\"si-detail-list-description\">MM:3 ns to 1 \u03bcs<br \/>\nSM:3 ns to 20 \u03bcs<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">RMS dynamic range<\/td>\n<td class=\"si-detail-list-description\">MM:26\/24 dB<br \/>\nSM:37\/35 dB<br \/>\n(the one-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level after 3-minutes averaging)<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Event dead zone<\/td>\n<td class=\"si-detail-list-description\">MM:0.8 m<br \/>\nSM:0.9 m<br \/>\n(measured at \u00b11.5 dB down from the peak of an unsaturated reflective event)<\/td>\n<\/tr>\n<tr>\n<td class=\"si-detail-list-title \">Attenuation dead zone<\/td>\n<td class=\"si-detail-list-description\">MM:4 m<br \/>\nSM:4 m<br \/>\n(measured at \u00b10.5 dB from the linear regression using an F\/UPC-type reflectance)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/article>\n<p>Check\u00a0<a href=\"https:\/\/woodcomm.ie\/catalogue\/brands\/softing\/\">Softing IT Network<\/a>. For further information, please\u00a0<a href=\"https:\/\/woodcomm.ie\/contact-us\/\">contact us<\/a>!<\/p>\n","protected":false},"excerpt":{"rendered":"<div id=\"c3680\" class=\"default-content-element\">\n<div class=\"ce-textpic ce-left ce-above\">\n<div class=\"ce-bodytext\">\n<h2 class=\"h2\">Certification of fiber optic networks made easy<\/h2>\n<p>Fiber optic cables are now an integral element in industrial networks, even for short distances, when it comes to meeting the demands for higher bandwidth. Installation of optical fibers, however, requires clean working conditions, correct procedures and a fair amount of knowledge. Cleanliness, in particular, plays an important role in the optical fibers themselves. According to a study by NTT Advanced Network Technology, dirty fiber end surfaces or connectors are responsible for up to 96 percent of network failures. Therefore, it is a good idea to select an easy-to-operate OTDR that can be connected via interfaces to an optical fiber microscope.<\/p>\n<h2 class=\"h2\">Smart Link Mapper (SLM)<\/h2>\n<p>Smart Link Mapper translates a difficult-to-understand OTDR measurement into a clear, easy-to-read diagram of the measured link. From the diagram, the pass\/fail information of each event on the link, such as connectors or splices, can be read directly. The often-difficult interpretation of an OTDR trace thus becomes child&#8217;s play.<\/p>\n<h2 class=\"h2\">Protection for launch fibers<\/h2>\n<p>The launch fibers can be wound onto the optional \u201cLaunch Cords\u201d and can be rolled out and coiled up again easily. The fiber is ideally protected &#8211; in the PRO variants, the coiling up takes place automatically.<\/p>\n<h2 class=\"h2\">The FiberXpert OTDR 5000 is the first choice for this<\/h2>\n<p>The handy, optical time domain reflectometer is available as a combi-device for multimode 850\/1300 nm and single mode 1310\/1550 nm. For both multimode and single mode fibers, the FiberXpert OTDR 5000 has a very high dynamic range with an event dead zone of &lt; 80 cm, meaning that it is designed for measuring and documenting short fiber links in accordance with standards and for identifying any faults. Further measurement functions, such as attenuation measurement and an optical power level analyzer, allow you to exactly determine the link attenuation and measure the output of active network components. The automatic pass\/fail analysis takes place in accordance with the TIA\/IEC limits. With this OTDR, standard-compliant tier 2 measurements are as easy as creating professional measurement protocols. Using the new matching optical fiber microscope &#8211; which can easily be connected to the OTDR via USB &#8211; fiber ends and link end surfaces can be quickly checked and assessed in accordance with IEC 61300-3-35. And all this at just the touch of a button.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>Learn More about our Partner Softing <a href=\"https:\/\/woodcomm.ie\/partners\/softing\/\" target=\"_blank\" rel=\"noopener\">here<\/a>.<br \/>\nFor further information, please <a href=\"https:\/\/woodcomm.ie\/contact-us\/\">contact us<\/a>!<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":34025,"template":"","meta":{"_acf_changed":false,"content-type":""},"product_brand":[],"product_cat":[1162,429,369],"product_tag":[],"class_list":["post-34023","product","type-product","status-publish","has-post-thumbnail","product_cat-softing","product_cat-softing-copper-testers","product_cat-testers","first","instock","shipping-taxable","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product\/34023","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/media\/34025"}],"wp:attachment":[{"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/media?parent=34023"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product_brand?post=34023"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product_cat?post=34023"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product_tag?post=34023"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}