{"id":34893,"date":"2025-04-07T09:26:25","date_gmt":"2025-04-07T09:26:25","guid":{"rendered":"https:\/\/woodcomm.ie\/catalogue\/?post_type=product&#038;p=34893"},"modified":"2025-09-08T00:59:06","modified_gmt":"2025-09-08T00:59:06","slug":"teltonika-managed-poe-ethernet-switch-tsw202","status":"publish","type":"product","link":"https:\/\/woodcomm.ie\/catalogue\/product\/teltonika-managed-poe-ethernet-switch-tsw202\/","title":{"rendered":"Teltonika Managed PoE+ Ethernet Switch TSW202"},"content":{"rendered":"<h2>Teltonika Managed PoE+ Ethernet Switch &#8211; TSW202<\/h2>\n<p>&nbsp;<\/p>\n<section class=\"av_textblock_section av-cars6pw-b74b9752d4c525b7a0e95d77019bd325\">\n<div class=\"avia_textblock\">\n<section class=\"av_textblock_section av-kpd045zy-21feb4e95d472fe2f523162c7ef122d3\">\n<div class=\"avia_textblock\">\n<div class=\"mt-8 first:mt-0\">\n<h2>Features:<\/h2>\n<\/div>\n<div class=\"mt-8 first:mt-0\">\n<div class=\"w-full default-list has-link\">\n<h3><span style=\"color: #000000;\"><strong>ETHERNET \u2014<\/strong><\/span><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\"><strong>ETH<\/strong><\/td>\n<td width=\"301\">Multi-layer managed 8 x ETH ports, 10\/100\/1000 Mbps supports auto MDI\/MDIX crossover<strong>\u00a0<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"301\"><strong>Fibre<\/strong><strong>\u00a0<\/strong><\/td>\n<td width=\"301\">2 x SFP ports<strong>\u00a0<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"301\"><strong>IEEE 802.3 series standards<\/strong><\/td>\n<td width=\"301\">802.3i, 802.3u, 802.3ab, 802.3x, 802.3z<strong>\u00a0<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u00a0<\/strong><\/p>\n<h3><strong>INDUSTRIAL PROTOCOLS \u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Profinet<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Profinet Class B conformance (available with optional order code)<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>POE OUT \u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>PoE ports<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Port 1 &#8211; 8<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>PoE standards<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>802.3af and 802.3at Alternative A (From batch 42)<\/h3>\n<h3>802.3af and 802.3at Alternative B (From batch 1-41)<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>PoE Max Power per Port (at PSE)<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>30 W<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Total PoE Power Budget (at PSE)<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>240 W<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Maximum Ethernet cable length<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>100 m<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>SERVICES <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>EtherNet\/IP<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Yes<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>SNMP V2, V3<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Yes<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>LLDP<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Yes<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Network Management<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>802.1p class of service, 802.1x port-based network access control, 802.1Q VLAN<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>NETWORK <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>MRP<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>MRP client role, MRP manager role<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>L2 features<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Loop protection, Forwarding table, VLAN, STP\/RSTP<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>DHCP<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>DHCP server, DHCP client, DHCP static leases capable of using MAC with wildcards<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Port Settings<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Enable\/disable, link speed control, port isolation, PoE Management, EEE (802.3az) management, Port Mirroring<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>L3 Features<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Static IPv4 routing, static IPv6 routing, DHCPv6 client, static IPv6 address<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>SECURITY <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Authentication<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>PAM \u2014 preshared key, Radius &amp; TACACS+, IP &amp; login attempts block<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>QOS <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>QOS<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Port priority, DSCP priority, 802.1p priority, TOS<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Scheduling method<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>SP\/WFQ\/WRR<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Bandwidth control<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Rate limiting, storm control<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Traffic Shaper<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Port-based shaping<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>DIAGNOSTICS <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Tools<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Cable diagnostic, ping, traceroute, nslookup<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Ping reboot<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Capability to restart PoE in a specific port<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>API <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Teltonika Networks Web API (beta) support<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Expand your device&#8217;s possibilities by using a set of configurable API endpoints to retrieve or change data. For more information, please refer to this documentation:\u00a0<a href=\"https:\/\/developers.teltonika-networks.com\/\">https:\/\/developers.teltonika-networks.com<\/a><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>SYSTEM CHARACTERISTICS <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>RAM<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>128MB, DDR3<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>FLASH storage<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>16 MB serial flash<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>FIRMWARE \/ CONFIGURATION <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>WEB UI<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Update FW from file, check FW on server, configuration profiles, configuration backup<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>FOTA<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Update FW<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>RMS<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Update FW\/configuration for multiple devices at once<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Keep settings<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Update FW without losing current configuration<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>FIRMWARE CUSTOMISATION <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Operating system<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>TSWOS (OpenWrt based Linux OS)<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Supported languages<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Busybox shell, Lua, C, C++<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Development tools<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>SDK package with build environment provided<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>PERFORMANCE SPECIFICATIONS <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Bandwidth (Non-blocking)<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>20 Gbps<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Forwarding rate<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>14.88 Mpps<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Packet buffer<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>512 KB<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>MAC address table size<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>8K entries<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Jumbo frame support<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>10000 bytes<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>POWER <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Connector<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>2-pin industrial DC power socket<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Input voltage range<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>7 \u2013 57 VDC<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>PoE-out input voltage range<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>44 \u2013 57 VDC<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Power consumption<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Idle: &lt; 3 W \/ Max: 8 W \/ PoE Max: 248 W<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>PHYSICAL INTERFACES <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Ethernet<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>8 x RJ45 ports, 10\/100\/1000 Mbps<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Fibre<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>2 x SFP ports<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Status LEDs<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>1 x Power LED, 1 x Aux LED, 16 x ETH status LEDs, 2 x SFP status LEDs<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Power<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>1 x 2-pin industrial DC power socket<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Reset<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Software reset button<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Other<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>1 x Grounding screw<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>PHYSICAL SPECIFICATION <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Casing material<\/strong><\/h3>\n<h3><strong>Dimensions (W x H x D)<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Anodized aluminum housing and panels<\/h3>\n<h3>132 x 44.2\u00a0x 122.2 mm<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Weight<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>610 g<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Mounting options<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>Integrated DIN rail bracket; wall mount and flat surface (additional kit needed)<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>OPERATING ENVIRONMENT <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Operating temperature<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>-40 \u00b0C to 75 \u00b0C<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Operating humidity<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>5% to 95% non-condensing<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Ingress Protection Rating<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>IP30<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>REGULATORY &amp; TYPE APPROVALS <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Regulatory<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>CE, UKCA, RCM, ANRT, FCC, IC, CB, NBTC, PROFINET, CITC, RoHS, REACH, WEEE, SDPPI (POSTEL), JATE, Kenya, ICASA, Giteki<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>EMC EMISSIONS &amp; IMMUNITY <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\">\n<h3><strong>Standards<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>EN 55032:2015 + A11:2020 + A1:2020<\/h3>\n<h3>EN 55035:2017 + A11:2020<\/h3>\n<h3>EN IEC 61000-3-2: 2019 + A1:2021<\/h3>\n<h3>EN 61000-3-3: 2013 + A1:2019 + A2:2021<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>ESD<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>EN 61000-4-2:2009<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Radiated Immunity<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>EN IEC 61000-4-3:2020<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>EFT<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>EN 61000-4-4:2012<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>Surge Immunity (AC Mains Power Port)<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>EN 61000-4-5:2014 + A1:2017<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>CS<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>EN 61000-4-6:2014<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"301\">\n<h3><strong>DIP<\/strong><\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<td width=\"301\">\n<h3>EN 61000-4-11:2020<\/h3>\n<h3><strong>\u00a0<\/strong><\/h3>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><strong>\u00a0<\/strong><\/h3>\n<h3><strong>SAFETY <\/strong><strong style=\"font-size: 16px;\">\u2014<\/strong><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"301\"><strong>Standards<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/td>\n<td width=\"301\"><strong>CE<\/strong>: EN IEC 62368-1:2020 + A11:2020<\/p>\n<p><strong>RCM<\/strong>: AS\/NZS 62368.1:2022<\/p>\n<p><strong>CB<\/strong>: IEC 62368-1:2018<\/p>\n<p><strong>\u00a0<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>\u00a0<\/strong><\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<\/section>\n<h4>For further information, please <a href=\"https:\/\/woodcomm.ie\/catalogue\/contact\/\">contact us.<\/a><\/h4>\n","protected":false},"excerpt":{"rendered":"<div class=\"font-bold text-sm md:mb-2\">MANAGED PoE+ ETHERNET SWITCH<\/div>\n<div class=\"font-semibold text-base hidden md:block\">TSW202 is a managed PoE+ Ethernet switch, designed to provide granular network management capabilities while centralising power distribution. This PoE+ switch enables flexibility over management and power supply and supports protocols, including EtherNet\/IP, PROFINET, and MRP. The TSW202 has 2 SFP ports and 8 Gigabit Ethernet ports providing 30 W of power each.<\/div>\n<p>View Datasheet Here :<\/p>\n<p><a href=\"https:\/\/woodcomm.ie\/catalogue\/wp-content\/uploads\/sites\/4\/2025\/04\/tsw202-datasheet-2024-v12-profinet.pdf\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-32878\" src=\"https:\/\/woodcomm.ie\/catalogue\/wp-content\/uploads\/sites\/4\/2022\/03\/PDF_file_icon.svg_-244x300.png\" alt=\"CNET CAT6 UTP COPPER CABLE 24 AWG LSZH 305M BOX 1\" width=\"69\" height=\"85\" srcset=\"https:\/\/woodcomm.ie\/catalogue\/wp-content\/uploads\/sites\/4\/2022\/03\/PDF_file_icon.svg_-244x300.png 244w, https:\/\/woodcomm.ie\/catalogue\/wp-content\/uploads\/sites\/4\/2022\/03\/PDF_file_icon.svg_.png 264w\" sizes=\"auto, (max-width: 69px) 100vw, 69px\" \/><\/a><\/p>\n","protected":false},"featured_media":34894,"template":"","meta":{"_acf_changed":false,"content-type":""},"product_brand":[],"product_cat":[397],"product_tag":[],"class_list":["post-34893","product","type-product","status-publish","has-post-thumbnail","product_cat-gigabit-poe-switch","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product\/34893","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/media\/34894"}],"wp:attachment":[{"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/media?parent=34893"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product_brand?post=34893"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product_cat?post=34893"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/woodcomm.ie\/catalogue\/wp-json\/wp\/v2\/product_tag?post=34893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}