EC Base Extender – Ethernet Over Coax Adapter – NV-ECLK-BSE

The NVT Phybridge EC-Base Extender Solution is designed to supercharge the downlink ports of a standard Ethernet switch, delivering 10/100Mbps symmetrical (full duplex) and PoE over Coax infrastructure with distances up to 6,000ft (1,830m). That’s 18X the reach of standard Ethernet switches, thus removing the costs and disruptions associated with multiple IDF closet requirements.

With the EC-Base Extender Solution, IP IoT devices can be connected to the existing Coax cabling infrastructure, delivering optimal performance while saving cost, time, and environmental e-waste. Furthermore, the cost savings realized by using the EC Extender Solution can enable system designers to transfer budget and resources towards higher-quality applications and IEEE-compliant IoT devices, including IP-enabled phones, cameras, access control, speakers, and even facilities lighting.

Extend the reach of standard PoE switches with the EC Extender Solution

View Datasheet Here :

CNET CAT6 UTP COPPER CABLE 24 AWG LSZH 305M BOX 1

SKU: NV-ECLK-BSE Category:

EC Base Extender – Ethernet Over Coax Adapter – NV-ECLK-BSE

EC-Base Technical Specifications

Model EC-Base
Part Number NV-ECLK-BSE
Dimensions • 10.09cm x 5.03cm x 2.57cm (LxWxH);
• 3.97” x 1.98” x 1.01” (LxWxH)
Weight 108g (3.81oz.)
Interface: Network Infrastructure side (CLEER) (1 BNC port: Coax cable (RG59, RG6, RG11)
Interface: IEEE Side (IP Device) (For General/PoE Switch) 1 RJ45 port: supports negotiation with IEEE 802.3 af/at switches
Power Supply PoE from standard PoE switch, or external power supply; maximum 50W if locally powered
Power Consumption 1W
Operating Temperature -58°F to +158°F (-50°C to +70°C) Tests conducted against international safety standard at maximum ambient temperatures of 60ºC at 30W and 55ºC at 50W
Humidity 10% to 95% (non-condensing) at 35° C
Mean Time Before Failure (MTBF) 20+ years
Rack Mount Model NV-RMEXT

EC-Base Compliance and Agency Approval

EMC Emissions: FCC Part 15, ICES-003, EN 55032:2012, EN 50121-4:2015
Class B
Immunity: EN 55024:2010, EN 50121-4:2015
Safety UL 60950-1 2nd Ed 2014-10-14, CAN/CSA C22.2 No. 60950-1-07 2nd Ed 2014-10
IEC 62368-1:2014, EN 62368-1:2014, AS/NZS 62368.1:2018
Environment RoHS Directives 2011/65 and 2015/863

For further information, please contact us.

Additional information

Ports

24 Port, 48 Port