Teltonika Managed PoE+ Ethernet Switch – TSW202
Features:
ETHERNET —
| ETH | Multi-layer managed 8 x ETH ports, 10/100/1000 Mbps supports auto MDI/MDIX crossover |
| Fibre | 2 x SFP ports |
| IEEE 802.3 series standards | 802.3i, 802.3u, 802.3ab, 802.3x, 802.3z |
INDUSTRIAL PROTOCOLS —
Profinet |
Profinet Class B conformance (available with optional order code) |
POE OUT —
PoE ports |
Port 1 – 8 |
PoE standards |
802.3af and 802.3at Alternative A (From batch 42)802.3af and 802.3at Alternative B (From batch 1-41) |
PoE Max Power per Port (at PSE) |
30 W |
Total PoE Power Budget (at PSE) |
240 W |
Maximum Ethernet cable length |
100 m |
SERVICES —
EtherNet/IP |
Yes |
SNMP V2, V3 |
Yes |
LLDP |
Yes |
Network Management |
802.1p class of service, 802.1x port-based network access control, 802.1Q VLAN |
NETWORK —
MRP |
MRP client role, MRP manager role |
L2 features |
Loop protection, Forwarding table, VLAN, STP/RSTP |
DHCP |
DHCP server, DHCP client, DHCP static leases capable of using MAC with wildcards |
Port Settings |
Enable/disable, link speed control, port isolation, PoE Management, EEE (802.3az) management, Port Mirroring |
L3 Features |
Static IPv4 routing, static IPv6 routing, DHCPv6 client, static IPv6 address |
SECURITY —
Authentication |
PAM — preshared key, Radius & TACACS+, IP & login attempts block |
QOS —
QOS |
Port priority, DSCP priority, 802.1p priority, TOS |
Scheduling method |
SP/WFQ/WRR |
Bandwidth control |
Rate limiting, storm control |
Traffic Shaper |
Port-based shaping |
DIAGNOSTICS —
Tools |
Cable diagnostic, ping, traceroute, nslookup |
Ping reboot |
Capability to restart PoE in a specific port |
API —
Teltonika Networks Web API (beta) support |
Expand your device’s possibilities by using a set of configurable API endpoints to retrieve or change data. For more information, please refer to this documentation: https://developers.teltonika-networks.com |
SYSTEM CHARACTERISTICS —
RAM |
128MB, DDR3 |
FLASH storage |
16 MB serial flash |
FIRMWARE / CONFIGURATION —
WEB UI |
Update FW from file, check FW on server, configuration profiles, configuration backup |
FOTA |
Update FW |
RMS |
Update FW/configuration for multiple devices at once |
Keep settings |
Update FW without losing current configuration |
FIRMWARE CUSTOMISATION —
Operating system |
TSWOS (OpenWrt based Linux OS) |
Supported languages |
Busybox shell, Lua, C, C++ |
Development tools |
SDK package with build environment provided |
PERFORMANCE SPECIFICATIONS —
Bandwidth (Non-blocking) |
20 Gbps |
Forwarding rate |
14.88 Mpps |
Packet buffer |
512 KB |
MAC address table size |
8K entries |
Jumbo frame support |
10000 bytes |
POWER —
Connector |
2-pin industrial DC power socket |
Input voltage range |
7 – 57 VDC |
PoE-out input voltage range |
44 – 57 VDC |
Power consumption |
Idle: < 3 W / Max: 8 W / PoE Max: 248 W |
PHYSICAL INTERFACES —
Ethernet |
8 x RJ45 ports, 10/100/1000 Mbps |
Fibre |
2 x SFP ports |
Status LEDs |
1 x Power LED, 1 x Aux LED, 16 x ETH status LEDs, 2 x SFP status LEDs |
Power |
1 x 2-pin industrial DC power socket |
Reset |
Software reset button |
Other |
1 x Grounding screw |
PHYSICAL SPECIFICATION —
Casing materialDimensions (W x H x D) |
Anodized aluminum housing and panels132 x 44.2 x 122.2 mm |
Weight |
610 g |
Mounting options |
Integrated DIN rail bracket; wall mount and flat surface (additional kit needed) |
OPERATING ENVIRONMENT —
Operating temperature |
-40 °C to 75 °C |
Operating humidity |
5% to 95% non-condensing |
Ingress Protection Rating |
IP30 |
REGULATORY & TYPE APPROVALS —
Regulatory |
CE, UKCA, RCM, ANRT, FCC, IC, CB, NBTC, PROFINET, CITC, RoHS, REACH, WEEE, SDPPI (POSTEL), JATE, Kenya, ICASA, Giteki |
EMC EMISSIONS & IMMUNITY —
Standards |
EN 55032:2015 + A11:2020 + A1:2020EN 55035:2017 + A11:2020EN IEC 61000-3-2: 2019 + A1:2021EN 61000-3-3: 2013 + A1:2019 + A2:2021 |
ESD |
EN 61000-4-2:2009 |
Radiated Immunity |
EN IEC 61000-4-3:2020 |
EFT |
EN 61000-4-4:2012 |
Surge Immunity (AC Mains Power Port) |
EN 61000-4-5:2014 + A1:2017 |
CS |
EN 61000-4-6:2014 |
DIP |
EN 61000-4-11:2020 |
SAFETY —
| Standards
|
CE: EN IEC 62368-1:2020 + A11:2020
RCM: AS/NZS 62368.1:2022 CB: IEC 62368-1:2018
|